Skip to content

SLA20-24 · Supralift II air controls

Waterproof controls. Emergency-open capability.

Complete the control side of your Supralift II system with a NEMA 4X enclosure, built-in push-button controls, and a pneumatic emergency-open valve.

  • NEMA 4X enclosure for demanding wet environments
  • 115V supply with a 24V control circuit
  • Pneumatic emergency-open function
Price per control box $961.10
List price $1,373.00

SKU SLA20-24

Control box only. The operator, airline, inline dryer, and safety devices are sold separately.

Unsure about your door or controls? Talk with our team.

Supralift air powered operator installed beside the exit door at Northdale Oil's North location

Built for the environment

Bring the air controls together.

The SLA20-24 combines the automatic air valve, filter regulator, gauge, shut-off valve, and push-button controls in one waterproof control assembly.

Its emergency-open valve provides pneumatic operation during an electrical power failure. Compressed air is still required. A trained installer should confirm accessory voltage and control compatibility.

Know what you are ordering

The control assembly, clearly specified.

Use this listing for a standalone control-box purchase. It is also available as the optional Add Control Box choice on the Supralift II operator.

Included with this product

  • NEMA 4X control enclosure with built-in push buttons
  • 2-position automatic air valve
  • Filter regulator with gauge and drain
  • Manual shut-off valve and 3/8-inch polyflow fittings
  • Pneumatic emergency-open push-button valve and plug-in primary power connection

Complete your installation

  • Supralift II operator and its standard mounting hardware
  • 3/8-inch polyflow airline and point-of-equipment inline dryer
  • Required safety reversing device
  • Application-specific stations, timers, sensors, and accessory wiring
Choose an operator and optional control box

Plan the installation

A better fit starts with the details.

Have a trained door professional confirm the door, air supply, controls, and safety requirements before installation.

SLA20-24 Supralift Emergency Open Control Box Specifications
Primary power supply115V
Control circuit24V
EnclosureNEMA 4X
Airline connection3/8-inch polyflow line
Emergency-open operationPneumatic valve; compressed air is required

Use a properly balanced door. Pusher springs are required for standard lift and high lift below 16 inches, and are sold separately. Do not use an air-line oiler. Follow the full installation manual. A reliable safety reversing device is required. The manual cautions that omitting a point-of-equipment inline dryer may void warranty coverage.

01 / INSTALLATION PARTS

Complete your control installation.

Plan the air supply, control stations and safety devices for the installation. Choose parts that match the control box and its voltage.

Air supply and plumbing

Plan the air supply before installation. The inline dryer, airline and plumbing reference are separate from the operator.

Norgren N90 inline air dryer with an elbow and a straight brass fitting

ILD10-14-N-A

Assembled Norgren N90 Inline Dryer for One Door

Reduce moisture in the air line supplying a single door with an assembled Norgren N90 inline dryer.

Pneumatic airline tubing coil

POLY38-100

3/8-Inch Polyflow Airline, 100 ft Roll

Supply the air connections in your installation with a 100 ft roll of 3/8-inch Polyflow airline.

Control stations

Choose a station for the installation environment. NEMA 4X is for wet locations; NEMA 1 is for dry service spaces.

PBK2 two-button control station

PBK2

Two-Button NEMA 4X Control Station

Add a two-button control station with a NEMA 4X enclosure for wet or corrosive control locations.

Part referencePBS2

PBS2

Two-Button NEMA 1 Control Station

Add a two-button station for dry service spaces, workshops, and other locations using NEMA 1 controls.

Safety photoeye sets

Choose a complete photoeye set with matching control voltage. Confirm the required reversing protection with your installer.

Representative Telco photoeye system

TELSET24

Telco 24VAC Photoeye Set with Adjustable Brackets

Specify a 24VAC Telco photoeye set with adjustable stainless-steel mounting brackets for your door-control installation.

Representative Telco photoeye system

TELSET-24DC

Telco 24VDC Photoeye Set with Adjustable Brackets

Specify a 24VDC Telco photoeye set with adjustable stainless-steel brackets for a matching control installation.

02 / OPTIONAL UPGRADES

Choose your timer option.

Factory socket preparation and a field-installed timer are different parts. Check the included components before selecting an option.

Timer options

Choose factory socket preparation when configuring a control box, or a field-installed timer with base. Check the part details for what is included.

Part referenceUPG-MTIMER

UPG-MTIMER

Factory Timer Option for Air Operator Control Boxes

Factory timer option for a compatible control box. Contact us to confirm the socket, timer and base supplied.

Contact for priceConfirm fit before ordering
Macromatic timer shown in the accessory catalog

TIMER-M

Macromatic Adjustable Field-Install Timer with Base

Add adjustable timing in the field with a Macromatic timer supplied with its base.

03 / REPLACEMENT PARTS

Service the controls and photoeyes.

Find the assembly you are servicing, then match the original part number, voltage, manufacturer and revision.

Airflow, pressure and mufflersMatch the original flow controls, filter regulator, gauge, drain or muffler. Some listed components are for a specific operator family.7 parts
Airflow, pressure and mufflers: Service the controls and photoeyes.
Part numberDescriptionDetails
FRGL
Liquid-filled 160 psi pressure gauge
Liquid-Filled 160 psi Filter-Regulator Gauge

Replace a matching filter-regulator gauge with the liquid-filled 160 psi version.

Ask about this part
FRGP
Standard 160 psi pressure gauge
Standard 160 psi Filter-Regulator Gauge

Replace a matching filter-regulator gauge with the standard 160 psi version.

Ask about this part
SLFR-72G-N
Norgren B72G series filter-regulator body
Norgren 80 SCFM Filter Regulator with Liquid-Filled Gauge

Replace a matching air-preparation assembly with a Norgren filter regulator specified for 80 SCFM and 0-160 psi.

Ask about this part
SLFR-72G-NO
Norgren B72G series filter-regulator body
Norgren 80 SCFM Filter Regulator, No Gauge

Replace a matching air-preparation assembly with a Norgren filter regulator specified for 80 SCFM and 0-160 psi.

Ask about this part
VV500P-4
Air Operator Ball-Valve Shut-Off Assembly

Replace a matching air-supply shut-off with the specified ball-valve assembly.

Ask about this part
SLPE18
Representative Porex air muffler
1/8-Inch NPT Porex Control-Box Muffler

Replace a matching control-box noise muffler with the specified 1/8-inch NPT Porex part.

Ask about this part
SLPE38
Representative Porex air muffler
3/8-Inch NPT Porex Muffler for NuMax Operators

Replace a matching NuMax operator noise muffler with the specified 3/8-inch NPT Porex part.

Ask about this part
Control valves and electrical partsMatch the valve configuration, voltage, manufacturer and part revision before replacing control-box components.4 parts
Control valves and electrical parts: Service the controls and photoeyes.
Part numberDescriptionDetails
SLV24-EP
24V Parker (Watts) Emergency-Open Replacement Valve

Replace a matching Parker (Watts) control valve with the 24V emergency-open version specified for the assembly.

Ask about this part
SLV24-P
24V Parker (Watts) Replacement Valve

Replace a matching Parker (Watts) control valve with the 24V version specified for the assembly.

Ask about this part
FRC24-P
24V Parker Replacement Solenoid Coil

Replace a matching Parker solenoid coil with the 24V new-style replacement.

Ask about this part
SLTR
Air Operator Control-Box Transformer

Replace a compatible control-box transformer with the 24V-output part specified for the assembly.

Confirm fit before ordering
Ask about this part
Photoeye replacement componentsService an existing compatible photoeye system with the matching amplifier, receiver, transmitter or brackets. Complete sets are listed with installation parts.4 parts
Photoeye replacement components: Service the controls and photoeyes.
Part numberDescriptionDetails
TEL24A
Telco 24V Replacement Photoeye Amplifier

Replace a matching Telco photoeye amplifier with the 24V PA11B302T component.

View details
TEL24R
Telco Replacement Photoeye Receiver

Replace a matching Telco photoeye receiver with the specified component.

View details
TEL24T
Telco Replacement Photoeye Emitter

Replace a matching Telco photoeye emitter with the specified component.

View details
PA10BKT
Stainless Steel Adjustable Bracket Set for Telco Photoeyes

Replace or add the adjustable stainless-steel brackets specified for compatible Telco photoeyes.

View details

American Garage Door Supply

Let’s match the system to your door.

Tell us your door height, track arrangement, shaft details, and existing controls. We can help identify the operator and accessories your installation requires.

Get product help

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare